Part Number Hot Search : 
01220 TQ150 MA3G762 TDA6403A 133AX LA3133 XXXBC V585M
Product Description
Full Text Search
 

To Download PQ-100D Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  specification pq-100b pq-100c model dc voltage rated current current range rated power output voltage adj. range line regulation load regulation setup, rise time hold up time (typ.) voltage range frequency range efficiency(typ.) input inrush current (typ.) leakage current working temp. power good working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload ac current (typ.) 5v ch1 ch1 -5v ch3 ch3 12v ch2 ch2 -12v ch4 ch4 5v -5v 15v -15v 10a 0.5a 3.5a 0.5a 8a 0.5a 3.5a 0.5a 2 ~ 10a 0 ~ 1a 0.5 ~ 4.5a 0 ~ 1a 2 ~ 8a 0 ~ 1a 0.5 ~ 4a 0 ~ 1a 100.5w 102.5w 80mvp-p 80mvp-p 250mvp-p 120mvp-p 80mvp-p 150mvp-p 150mvp-p 80mvp-p ch1:4.75 ~ 5.5v ch1:4.75 ~ 5.5v 3.0% 6.0% 12% 6.0% 6.0% 6.0% 6.0% 2.0% 1.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% 3.0% 1.0% 1.0% 1.0% 1.0% 5.0% 5.0% 1.0% 5.0% 1200ms, 50ms at full load 80ms at full load 100 ~ 264vac 141 ~370vdc (90 ~ 100vac 90% load max.) 47 ~ 63hz 72% 74% 3a/115vac 1.5a/230vac cold start 50a <1ma /240vac 105% ~ 135% rated output power protection type : hiccup mode, recovers automatically after fault co ndition is removed protection type : hiccup mode, recovers automatically after fault co ndition is removed -10 ~ +50 ,60 (refer to output load derating curve) with cooling fan 1ms 20 ~ 90% rh non-condensing -20 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 50 ) 10 ~ 500hz, 2g 10min./1cycle, period for 60min. each along x, y, z axes 258.6k hrs min. mil-hdbk-217f (25 ) 177.8*107.95*46mm (l*w*h) 0.56kg; 24pcs/14.5kg/1.19cuft file name:pq-100-spec 2010-10-18 ch1: 5.75 ~ 6.75vdc over voltage safety standards harmonic current ems immunity ul60950-1, tuv en60950-1 approved compliance to en55022 (cispr22) class b compliance to en61000-3-2,-3 compliance to light industry level, criteria a en61000-4-2,3,4,5,6,11; env50204, features : p q - 1 0 0 s e r i e s environment safety & function emc (note 4) protection emi conduction & radiation withstand voltage isolation resistance i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh ripple & noise (max.) note.2 voltage tolerance note.3 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) universal ac input / full range protections: short circuit / overload / over voltage cooling by free air convection with power good signal output(optional) 100% full load burn-in test fixed switching frequency at 45khz 2 years warranty output number 100w quad output switching power supply
specification PQ-100D pq-100e model dc voltage rated current current range rated power output voltage adj. range line regulation load regulation setup, rise time hold time (typ.) voltage range frequency range efficiency (typ.) input inrush current (typ.) leakage current working temp. power good working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing over load ac current (typ.) 5v 24v -12v 5v 15v 12v 24v 5a 2a 0.5a 8a 0.6a 3a 0.6a 2 ~ 5a 0.4 ~ 2a 0.5 ~ 4.5a 0 ~ 1a 2 ~ 8a 0 ~ 1a 0.5 ~ 3a 0 ~ 1a 103w 99.4w 80mvp-p 180mvp-p 120mvp-p 120mvp-p 150mvp-p 120mvp-p 120mvp-p 80mvp-p ch1:4.75 ~ 5.5v ch1:4.75 ~ 5.5v 2.0% 10% 6.0% 6.0% 6.0% 6.0% 6.0% 2.0% 1.0% 1.0% 1.0% 5.0% 1.0% 1.0% 1.0% 3.0% 1.0% 1.0% 1.0% 1.0% 5.0% 3.0% 1.0% 5.0% 1200ms, 50ms at full load 80ms at full load 100 ~ 264vac 141 ~370vdc (90 ~ 100vac 90% load max.) 47 ~ 63hz 77% 74% 3a/115vac 1.5a/230vac cold start 50a <1ma /240vac 105% ~ 135% rated output power protection type : hiccup mode, recovers automatically after fault co ndition is removed protection type : hiccup mode, recovers automatically after fault co ndition is removed -10 ~ +50 ,60 (refer to output load derating curve) with cooling fan 1ms 20 ~ 90% rh non-condensing -20 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 50 ) 10 ~ 500hz, 2g 10min./1cycle, period for 60min. each along x, y, z axes 258.6k hrs min. mil-hdbk-217f (25 ) 177.8*107.95*46mm (l*w*h) 0.56kg; 24pcs/14.5kg/1.19cuft file name:pq-100-spec 2010-10-18 ch1: 5.75 ~ 6.75vdc over voltage safety standards harmonic current ems immunity ul60950-1, tuv en60950-1 approved compliance to en55022 (cispr22) class b compliance to en61000-3-2,-3 compliance to light industry level, criteria a en61000-4-2,3,4,5,6,11; env50204, features : p q - 1 0 0 s e r i e s environment safety & function emc (note 4) protection emi conduction & radiation withstand voltage isolation resistance i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh ripple & noise (max.) note.2 voltage tolerance note.3 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) universal ac input / full range protections:short circuit/over load/over voltage cooling by free air convection with power good signal output(optional) 100% full load burn-in test fixed switching frequency at 45khz 2 years warranty output number ch1 ch1 ch3 ch3 ch2 ch4 ch4 100w quad output switching power supply 12v 2a ch2
file name:pq-100-spec 2010-10-18 unit:mm load (%) mechanical specification static characteristics (b) ambient temperature ( ) (horizontal) -10 -10 00 10 20 30 40 50 60 20 40 60 80 100 input voltage (v) 60hz 90 100 110 120 140 160 180 200 220 240 260 300 250 200 150 100 50 25 output voltage (v) output ripple (mvp-p) ta=25 12 13 87 11 10 9 4.8 5.0 5.2 4.4 4.6 4.2 4.0 17cfm forced air cooling(20cm) natural convection cooling 100w quad output switching power supply 12v 5v 5v +12v -12v derating curve block diagram fosc : 45khz 177.8 165.1 107.95 95.25 1 cn2 +5v adj 43 2 65 98 7 11 10 cn1 1 13 3 5 4- 3.96 46 12 2 4 6.35 6.35 dc output connector (cn2) : molex 5273-06,07 or equivalent pin no. 1,2,3 4,5,6,7 8,9 10 11 12 13 assignment v1 com v2 power good(option) v3 no pin v4 mating housing molex 5195 or equivalent terminal molex 5194 or equivalent ac input connector (cn1) : molex 5273-05 or equivalent pin no. 1 2,4 35 assignment mating housing molex 5195 molex 5194 or equivalent or equivalent terminal fg no pin ac/n ac/l 3 max. ac fuse t4a/250v fs1 p q - 1 0 0 s e r i e s o.l.p. i/p fg circuit detection emi filter rectifiers & filter power switching filter filter filter filter & & & & rectifiers rectifiers rectifiers rectifiers v1 v2 v3 v4 com control pwm o.v.p. regulator regulator


▲Up To Search▲   

 
Price & Availability of PQ-100D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X